The PARTITION Procedure
OUTPUT Statement
OUTPUT OUT=CAS-libref.data-table <options>;
The OUTPUT statement creates a data table to contain the sampled observations and stratification information for the sample.
You must specify the following option:
- OUT=CAS-libref.data-table
-
names the output data table for PROC PARTITION to use. You must specify this option before any other options. CAS-libref.data-table is a two-level name, where
- CAS-libref
refers to a collection of information that is defined in the LIBNAME statement and includes the
caslib, which includes a path to where the data table is to be stored, and a session identifier, which defaults to the active session but which can be explicitly defined in the LIBNAME statement. For more information about CAS-libref, see the section Using CAS Sessions and CAS Engine Librefs.- data-table
specifies the name of the output data table.
This table includes variables that are specified in the COPYVARS= option. In the K-fold partition case, the output includes one more column, _Fold_. In other cases, if you also specify the PARTIND option in the PROC PARTITION statement, the output includes one more column, _PartInd_. In the oversampling case, an additional column, _Freq_, is provided. It is calculated as the ratio of target level’s proportion in the population to its proportion in the sample. _Fold_, _PartInd_ and _Freq_ are reserved names. If they exist in the input data table and you specify them in the COPYVARS= option, you need to use the FOLDNAME=, PARTINDNAME= and FREQNAME= options to change the generated columns’ names.
You can also specify the following options:
-
COPYVAR=variable
COPYVARS=(variables) -
lists one or more variables from the input data table to be transferred to the output data table.
If the COPYVARS= option is not specified, all the variables in the input data table are transferred to the output data table.
- FOLDNAME=fold-name
renames the output data table’s _Fold_ column (which is generated when k-fold partitioning is requested) to the specified fold-name.
- FREQNAME=freq-name
renames the output data table’s _Freq_ column (which is generated when oversampling is requested) to the specified freq-name.
- PARTINDNAME=partition-indicator-name
renames the generated partition indicator, _PartInd_, in the output data table to the specified partition-indicator-name.
- SAMPLEFREQNAME=sample-frequency-name
renames the generated sample frequency variable,