The SEQTEST Procedure

Example 104.3 Testing an Effect with Early Stopping to Accept

(View the complete code for this example.)

This example demonstrates a two-sided group sequential test that uses an error spending design with early stopping to accept the null hypothesis . The example is similar to Example 104.2 but with early stopping to accept .

A study is conducted to examine the effects of Age (years), Weight (kg), RunTime (time in minutes to run 1.5 miles), RunPulse (heart rate while running), and MaxPulse (maximum heart rate recorded while running) on Oxygen (oxygen intake rate, ml per kg body weight per minute). The primary interest is whether oxygen intake rate is associated with weight.

The hypothesis is tested using the following linear model:

The null hypothesis is , where is the regression parameter for the variable Weight. Suppose that is the reference improvement that should be detected at a 0.90 level. Then the maximum information can be derived in the SEQDESIGN procedure.

Following the derivations in the section Test for a Parameter in the Regression Model in Chapter 103: The SEQDESIGN Procedure, the required sample size can be derived from

where is the variance of the response variable in the regression model, is the proportion of variance of Weight explained by other covariates, and is the variance of Weight.

Further suppose that from past experience, , , and . Then the required sample size can be derived using the SAMPLESIZE statement in the SEQDESIGN procedure.

The following statements invoke the SEQDESIGN procedure and request a three-stage group sequential design for normally distributed data to test the null hypothesis of a regression parameter against the alternative :

ods graphics on;
proc seqdesign altref=0.10;
   OBFErrorFunction: design method=errfuncgamma
                            stop=accept
                            nstages=3
                            info=cum(2 3 4);

   samplesize model=reg( variance=5 xvariance=64 xrsquare=0.10);
   ods output Boundary=Bnd_Fit;
run;

By default (or equivalently if you specify ALPHA=0.05 and BETA=0.10), the procedure uses a Type I error probability 0.05 and a Type II error probability 0.10. The ALTREF=0.10 option specifies a power of at the alternative hypothesis . The INFO=CUM(2 3 4) option specifies that the study perform the first interim analysis with information proportion —that is, after half of the total observations are collected.

The ODS OUTPUT statement with the BOUNDARY=BND_FIT option creates an output data set named BND_FIT which contains the resulting boundary information for the subsequent sequential tests.

The "Design Information" table in Output 104.3.1 displays design specifications and derived statistics. Since the alternative reference is specified, the maximum information is derived.

Output 104.3.1: Error Spending Design Information

The SEQDESIGN Procedure
Design: OBFErrorFunction

Design Information
Statistic DistributionNormal
Boundary ScaleStandardized Z
Alternative HypothesisTwo-Sided
Early StopAccept Null
MethodError Spending
Boundary KeyBoth
Alternative Reference0.1
Number of Stages3
Alpha0.05
Beta0.1
Power0.9
Max Information (Percent of Fixed Sample)103.9245
Max Information1091.972
Null Ref ASN (Percent of Fixed Sample)75.00521
Alt Ref ASN (Percent of Fixed Sample)101.8099


The "Boundary Information" table in Output 104.3.2 displays information level, alternative reference, and boundary values at each stage.

Output 104.3.2: Boundary Information

Boundary Information (Standardized Z Scale)
Null Reference = 0
_Stage_ AlternativeBoundary Values
Information LevelReferenceLowerUpper
ProportionActualNLowerUpperBetaBeta
10.5000545.986247.39463-2.336632.33663-0.449370.44937
20.7500818.979271.09195-2.861782.86178-1.135831.13583
31.00001091.97294.78926-3.304503.30450-1.914281.91428


With ODS Graphics enabled, a detailed boundary plot with the rejection and acceptance regions is displayed, as shown in Output 104.3.3. The boundary plot also displays the information level and critical value for the corresponding fixed-sample design.

Output 104.3.3: Boundary Plot

Boundary Plot


With the MODEL=REG option in the SAMPLESIZE statement, the "Sample Size Summary" table in Output 104.3.4 displays the parameters for the sample size computation.

Output 104.3.4: Required Sample Size Summary

Sample Size Summary
TestReg Parameter
Parameter0.1
Variance5
X Variance64
R Square (X)0.1
Max Sample Size94.78926
Expected Sample Size (Null Ref)68.41207
Expected Sample Size (Alt Ref)92.86057


The "Sample Sizes" table in Output 104.3.5 displays the required sample sizes for the group sequential clinical trial.

Output 104.3.5: Required Sample Sizes

Sample Sizes (N)
Z Test for Regression Parameter
_Stage_Fractional NCeiling N
NInformationNInformation
147.39546.048553.0
271.09819.072829.4
394.791092.0951094.4


Thus, 48, 72, and 95 individuals are needed in stages 1, 2, and 3, respectively. Since the sample sizes are derived from estimated values of , , and , the actual information levels might not achieve the target information levels. Thus, instead of specifying sample sizes in the protocol, you can specify the maximum information levels. Then if an actual information level is much less than the target level, you can increase the sample sizes for the remaining stages to achieve the desired information levels and power.

Suppose that 48 individuals are available at stage 1. Output 104.3.6 lists the first 10 observations of the trial data.

Output 104.3.6: Clinical Trial Data

First 10 Obs in the Trial Data

ObsOxygenAgeWeightRunTimeRunPulseMaxPulse
154.55214487.767611.6949178.435181.607
252.28214075.48539.8872184.433183.667
362.18714489.06388.7950155.540167.108
465.32694267.73108.4577162.926173.877
559.98093793.19029.3228179.033180.144
652.55884775.904412.0385177.753175.033
751.78384073.542211.6607175.838178.140
857.00244381.286111.2219160.963171.770
948.07754485.229013.1789173.722176.548
1068.33573880.24908.5066171.824184.011


The following statements use the REG procedure to estimate the slope and its associated standard error at stage 1:

proc reg data=Fit_1;
   model Oxygen=Age Weight RunTime RunPulse MaxPulse;
   ods output ParameterEstimates=Parms_Fit1;
run;

The following statements create and display (in Output 104.3.7) the input data set that contains slope and its associated standard error for the SEQTEST procedure:

data Parms_Fit1;
   set Parms_Fit1;
   if Variable='Weight';
   _Scale_='MLE';
   _Stage_= 1;
   keep _Scale_ _Stage_ Variable Estimate StdErr;
run;

proc print data=Parms_Fit1;
   title 'Statistics Computed at Stage 1';
run;

Output 104.3.7: Statistics Computed at Stage 1

Statistics Computed at Stage 1

ObsVariableEstimateStdErr_Scale__Stage_
1Weight0.046600.04308MLE1


The following statements invoke the SEQTEST procedure to test for early stopping at stage 1:

ods graphics on;
proc seqtest Boundary=Bnd_Fit
             Parms(testvar=Weight)=Parms_Fit1
             infoadj=none
             errspendadj=errfuncgamma
             stopprob
             order=lr
             ;
   ods output Test=Test_Fit1;
run;

The BOUNDARY= option specifies the input data set that provides the boundary information for the trial at stage 1, which was generated in the SEQDESIGN procedure. The PARMS=PARMS_FIT1 option specifies the input data set PARMS_FIT1 that contains the test statistic and its associated standard error at stage 1, and the TESTVAR=WEIGHT option identifies the test variable WEIGHT in the data set. The INFOADJ=NONE option maintains the information level for stage 2 at the value provided in the BOUNDARY= data set.

The ORDER=LR option uses the LR ordering to derive the p-value, the unbiased median estimate, and the confidence limits for the regression slope estimate. The ERRSPENDADJ=ERRFUNCGAMMA option adjusts the boundaries with the updated error spending values generated from a gamma cumulative error spending function.

The ODS OUTPUT statement with the TEST=TEST_FIT1 option creates an output data set named TEST_FIT1 which contains the updated boundary information for the test at stage 1. The data set also provides the boundary information that is needed for the group sequential test at the next stage.

The "Design Information" table in Output 104.3.8 displays the design specifications. By default (or equivalently if you specify BOUNDARYKEY=ALPHA), the boundary values are modified for the new information levels to maintain the Type I level. The maximum information remains the same as in the BOUNDARY= data set, but the derived Type II error probability and power are different because of the new information level.

Output 104.3.8: Design Information

The SEQTEST Procedure

Design Information
BOUNDARY Data SetWORK.BND_FIT
Data SetWORK.PARMS_FIT1
Statistic DistributionNormal
Boundary ScaleStandardized Z
Alternative HypothesisTwo-Sided
Early StopAccept Null
Number of Stages3
Alpha0.05
Beta0.10007
Power0.89993
Max Information (Percent of Fixed Sample)103.9498
Max Information1091.97232
Null Ref ASN (Percent of Fixed Sample)75.15846
Alt Ref ASN (Percent of Fixed Sample)101.8296


With the STOPPROB option, the "Expected Cumulative Stopping Probabilities" table in Output 104.3.9 displays the expected stopping stage and the cumulative stopping probability of accepting the null hypothesis at each stage under various hypothetical references , where is the alternative reference and by default. You can specify other values for with the CREF= option.

Output 104.3.9: Stopping Probabilities

Expected Cumulative Stopping Probabilities
Reference = CRef * (Alt Reference)
CRefExpected
Stopping Stage
SourceStopping Probabilities
Stage_1Stage_2Stage_3
0.00001.895Accept Null0.333040.766070.95000
0.50002.409Accept Null0.176800.409470.62828
1.00002.918Accept Null0.026360.054530.10007
1.50002.997Accept Null0.001090.001660.00242


The "Test Information" table in Output 104.3.10 displays the boundary values for the test statistic. By default (or equivalently if you specify BOUNDARYSCALE=STDZ), these statistics are displayed with the standardized Z scale. The information level at stage 1 is derived from the standard error in the PARMS= data set,

Output 104.3.10: Sequential Tests

Test Information (Standardized Z Scale)
Null Reference = 0
_Stage_ AlternativeBoundary ValuesTest
Information LevelReferenceLowerUpperWeight
ProportionActualLowerUpperBetaBetaEstimateAction
10.4934538.7887-2.321182.32118-0.430330.430331.08174Continue
20.7500818.9792-2.861782.86178-1.136231.13623. 
31.00001091.972-3.304503.30450-1.914311.91431. 


At stage 1, the standardized Z statistic 1.08174 is greater than the upper boundary 0.43033, so the trial continues to the next stage.

With ODS Graphics enabled, a boundary plot with test statistics is displayed, as shown in Output 104.3.11. As expected, the test statistic is in the continuation region.

Output 104.3.11: Sequential Test Plot

Sequential Test Plot


The following statements use the REG procedure to estimate the slope and its associated standard error at stage 2:

proc reg data=Fit_2;
   model Oxygen=Age Weight RunTime RunPulse MaxPulse;
   ods output ParameterEstimates=Parms_Fit2;
run;

Note that the data set Fit_2 contains both the data from stage 1 and the data from stage 2,

The following statements create and display (in Output 104.3.12) the input data set that contains slope and its associated standard error at stage 2 for the SEQTEST procedure:

data Parms_Fit2;
   set Parms_Fit2;
   if Variable='Weight';
   _Scale_='MLE';
   _Stage_= 2;
   keep _Scale_ _Stage_ Variable Estimate StdErr;
run;


proc print data=Parms_Fit2;
   title 'Statistics Computed at Stage 2';
run;

Output 104.3.12: Statistics Computed at Stage 2

Statistics Computed at Stage 2

ObsVariableEstimateStdErr_Scale__Stage_
1Weight0.029250.03490MLE2


The following statements invoke the SEQTEST procedure to test for early stopping at stage 2:

ods graphics on;
proc seqtest Boundary=Test_Fit1
             Parms(testvar=Weight)=Parms_Fit2
             errspendadj=errfuncgamma
             order=lr
             pss
             plots=(asn power)
             ;
   ods output Test=Test_Fit2;
run;

The BOUNDARY= option specifies the input data set that provides the boundary information for the trial at stage 2, which was generated by the SEQTEST procedure at the previous stage. The PARMS= option specifies the input data set that contains the test statistic and its associated standard error at stage 2, and the TESTVAR= option identifies the test variable in the data set.

Since the data set PARMS_FIT2 does not contain the test information at stage 1, the information level at stage 1 in the TEST_FIT1 data set is used to generate boundary values for the test.

The ORDER=LR option uses the LR ordering to derive the p-value, unbiased median estimate, and confidence limits for the regression slope estimate.

The ODS OUTPUT statement with the TEST=TEST_FIT2 option creates an output data set named TEST_FIT2 which contains the updated boundary information for the test at stage 2. The data set also provides the boundary information that is needed for the group sequential test at the next stage.

The "Design Information" table in Output 104.3.13 displays design specifications. By default (or equivalently if you specify BOUNDARYKEY=ALPHA), the boundary values are modified for the new information levels to maintain the Type I level.

Output 104.3.13: Design Information

The SEQTEST Procedure

Design Information
BOUNDARY Data SetWORK.TEST_FIT1
Data SetWORK.PARMS_FIT2
Statistic DistributionNormal
Boundary ScaleStandardized Z
Alternative HypothesisTwo-Sided
Early StopAccept Null
Number of Stages3
Alpha0.05
Beta0.10009
Power0.89991
Max Information (Percent of Fixed Sample)103.9566
Max Information1091.97232
Null Ref ASN (Percent of Fixed Sample)75.18254
Alt Ref ASN (Percent of Fixed Sample)101.8349


The derived Type II error probability and power are different because of the new information levels.

With the PSS option, the "Power and Expected Sample Sizes" table in Output 104.3.14 displays powers and expected mean sample sizes under various hypothetical references , where is the alternative reference and are the default values in the CREF= option.

Output 104.3.14: Power and Expected Sample Size Information

Powers and Expected Sample Sizes
Reference = CRef * (Alt Reference)
CRefPowerSample Size
Percent
Fixed-Sample
0.00000.0250075.1825
0.50000.3715488.5975
1.00000.89991101.8349
1.50000.99758103.8843


With the PLOTS=ASN option, the procedure displays a plot of expected sample sizes under various hypothetical references, as shown in Output 104.3.15. By default, expected sample sizes under the hypotheses , , are displayed, where is the alternative reference.

Output 104.3.15: ASN Plot

ASN Plot


With the PLOTS=POWER option, the procedure displays a plot of the power curves under various hypothetical references for all designs simultaneously, as shown in Output 104.3.16. By default, powers under hypothetical references are displayed, where by default. You can specify values with the CREF= option. The values are displayed on the horizontal axis.

Output 104.3.16: Power Plot

Power Plot


Under the null hypothesis, , the power is 0.025, which is the upper Type I error probability. Under the alternative hypothesis, , the power is 0.89991, which is one minus the Type II error probability, as displayed in the "Design Information" table in Output 104.3.13.

The "Test Information" table in Output 104.3.17 displays the boundary values for the test statistic with the default standardized Z scale. At stage 2, the standardized slope estimate 0.83805 is between the lower and upper boundary values. The trial stops to accept the null hypothesis that the variable Weight has no effect on the oxygen intake rate after adjusting for other covariates.

Output 104.3.17: Sequential Tests

Test Information (Standardized Z Scale)
Null Reference = 0
_Stage_ AlternativeBoundary ValuesTest
Information LevelReferenceLowerUpperWeight
ProportionActualLowerUpperBetaBetaEstimateAction
10.4934538.7887-2.321182.32118-0.430330.430331.08174Continue
20.7517820.8509-2.865052.86505-1.142391.142390.83805Accept Null
31.00001091.972-3.304503.30450-1.914081.91408. 


Since the data set PARMS_FIT2 contains the test information only at stage 2, the information level at stage 1 in the TEST_FIT1 data set is used to generate boundary values for the test.

With ODS Graphics enabled, a boundary plot with test statistics is displayed, as shown in Output 104.3.18. As expected, the test statistic is in the acceptance region between the lower and upper boundaries at the final stage.

Output 104.3.18: Sequential Test Plot

Sequential Test Plot


After a trial is stopped, the "Parameter Estimates" table in Output 104.3.19 displays the stopping stage, parameter estimate, unbiased median estimate, confidence limits, and the p-value under the null hypothesis . As expected, the p-value 0.3056 is not significant at the level, and the confidence interval does contain the value zero. The p-value, unbiased median estimate, and confidence limits depend on the ordering of the sample space , where k is the stage number and z is the standardized Z statistic. With the specified LR ordering, the p-values are computed with the ordering if . See the section Available Sample Space Orderings in a Sequential Test for a detailed description of the LR ordering.

Output 104.3.19: Parameter Estimates

Parameter Estimates
LR Ordering
ParameterStopping
Stage
MLEp-Value for
H0:Parm=0
Median
Estimate
95% Confidence Limits
Weight20.0292510.30560.037080-0.033680.10532